West Whiteland Township Planning Commission in West Whiteland Township met on Tuesday, October 6, 2026. County Brief published an AI-labeled recap below, drawn from the official packet. Use the original documents or the official site for the full record, and browse other West Whiteland Township Planning Commission meetings from West Whiteland Township.
Meeting Recap AI-generated summary
County Brief is an independent local news service from Wisdom Digital Media, Inc. It is not affiliated with, endorsed by, or acting on behalf of any government agency. Meeting agendas and minutes come from each town's or school district's official website; every meeting links to the original document. Official sources
West Whiteland Township’s Planning Commission met on October 6, 2026. It approved the August 18 meeting minutes, 7-0. After reviewing Exton Market Realty’s proposed retail building and car wash at 222 N. Pottstown Pike, the Commission passed a 7-0 motion recommending that the Board of Supervisors approve the land development plan as a Final Plan, subject to 21 conditions. Those conditions include DEP approval of a sewage planning exemption, floodplain mapping steps, fees, and resolution of remaining staff and consultant concerns. The Commission also discussed truck deliveries, utilities, sidewalks, traffic, and stormwater management. It took no action on the E.N. Peirce Middle School land development plan; the applicant said it would revise plans and hoped to resubmit in early December. Discussion included proposed school additions, synthetic athletic surfaces, stormwater facilities, pedestrian safety, and traffic queuing. In new business, members agreed that Commission meetings would begin at 6:30 p.m. starting in 2027. The next meeting was announced for October 20, with review of the Oak Knoll subdivision plan for the Shenkin property. The minutes record no public comment on non-agenda items or on the Exton plan.
Decided
- August 18 meeting minutes Approved, 7–0From the document: “MOTION: To approve the minutes of August 18, 2026, as presented”
- Exton Market land development plan ApprovedFrom the document: “To recommend that the Board of Supervisors approve the land development plan of Exton Market Realty, LLC”
Discussed, no vote recorded
- Planning Commission meeting start time
- E.N. Peirce Middle School land development proposal
- Exton Market delivery access, utilities, sidewalks, traffic, and stormwater
- Pedestrian safety and traffic queuing at Peirce Middle School
Coming up
- Next Planning Commission meeting, including review of the Oak Knoll subdivision plan for the Shenkin property (October 20)
- West Goshen conditional use hearing for the Peirce Middle School project (October 19, 2026)
- Peirce Middle School applicant hopes to resubmit revised plans (early December)
How this recap was made
Written by AI on Nov 19, 2026 from the official minutes linked on this page, then checked by software, not by a reporter. An item is listed under Decided only when the minutes' own wording shows the action, and that wording is quoted. A vote count appears only when the minutes give it. Everything else is listed as discussed. This is not an official record; the linked document is. More on how County Brief works
Items in the posted packet
Taken from the official agenda index. This is a list of attachments, not a recap of votes.
- SSM review dated September 29, 2026
- RVE review dated August 4, 2026
- Theurkauf review dated September 25, 2026
- Bowman review dated September 29, 2026
- “Modified Sidewalk Alignment Option” prepared by Bowman, dated September 29, 2026
- Chester County Planning Commission review dated September 2, 2026
- Plan set prepared by Dynamic Engineering, dated July 16, 2025, most recently revised September 15,
- Section 325-13.C(2) – A variance was granted to permit an impervious coverage of 98.1% when a 70% percent maximum is usually permitted within the TC District
- Section 325-37.A(2)(a) – A variance was granted to not require a raised landscape island at the end of the parking bay in the retail store parking lot for delivery vehicle circulation
- Section 325-13.C(5)(a)[3] – A variance was granted to permit a building setback of less than 25 feet from property lines that adjoin the Town Center Zoning District
- Section 325-39.H(5) – A variance was granted to permit drive-through facilities without a bypass lane. The following variance is no longer required:
- The waiver requests on sheet 3 shall be rearranged to be in numerical order. ZONING
- Section 281-47.C – The plans note that a fee-in-lieu of Open Space is offered for consideration.
- Section 270-17.A(1)(a) – The applicant shall provide the Township with a letter of adequacy from the Conservation District for an erosion and sediment control plan prior to the Township endorsing the plan
- Sections 270-32.A(3)&(4) – The owner’s acknowledgement statement and design engineer’s signature blocks on sheet 10 shall be signed before the Township endorses the plan
- Section 270-32.B(13) – Profiles shall be provided for the storm sewers
- Profiles shall be provided for Inlet #111 to the Arcadia system
- Section 281-48.C(3)(i) – Light fixtures shall not exceed 3000K CCT. The plans shall verify the same. Decorative fixture on sheet 16 and light fixture on sheet 17 shall indicate their CCT levels
- Improvements are proposed within the Miller Way right-of-way. Given the extent of the improvements, a future maintenance agreement which covers such improvements should be considered
- The plans shall note that no cart corrals are proposed
- All proposed traffic control signs shall be identified on the plans. The stop bar located in the parking lot between the retail store and Car Wash shall include a stop sign. We defer to Bowman regarding this matter
- The plans shall note that a Township Street Occupancy Permit is required before any work is performed within the Township’s right-of-way
- The existing storm pipe crossing shall be added downstream of “PROP. SAN C/O INV(6”): 307.61” on the “PROFILE VIEW OF CAR WASH TO SAN. MH #S101” on Sheet 14 of 38
- The proposed UGET and gas crossings to be added to “PROFILE VIEW OF CAR WASH TO SAN. MH #S101” on Sheet 14 of 38
- The two proposed UGET crossings shall be added to “PROFILE VIEW OF RETAIL STORE TO SAN. MH #S101” on Sheet 14 of 38
- Pottstown Pike Corridor - §281-70.B (SLDO) requires the site element screen along Pottstown Pike to define and reinforce the corridor. This issue is resolved
- Street Trees – One street tree is required for each 50 feet of road frontage per §281-36.D (SLDO). This issue is resolved
- Site Element Screen – §281-35.G (SLDO) requires a low site element screen for drive through stacking lanes and a high screen around non-decorative fenced trash enclosures. This issue has been resolved
- Species Selection - §281-33.C.4 (SLDO) requires that plants be suited to the conditions wherein they will be placed. This issue has been resolved
- Cost Estimate – A landscape cost estimate will be required upon approval of the final plan in accordance with section 281-33.C.6.i (SLDO)
- Details for each type of proposed curb ramp should be provided. The only curb ramp detail currently depicted is a Parallel Curb Ramp Detail
- For each ramp design, provide a label stating the type of ramp that is proposed and a reference to RC-67M
- The applicant should discuss how dripping water from vehicles exiting the car wash will be mitigated, especially during cold weather when icing may occur
- Land disturbance and land development activities that occur within Chester County must comply with the County-wide Act 167 Stormwater Management Plan for Chester County, PA (August
- and the associated Act 167 stormwater management ordinance standards adopted by each municipality
- A Pennsylvania Department of Transportation (PennDOT) permit is required for new or revised access and should be identified on the final plan as required by Section 508(6) of the Municipalities Planning Code
- The Applicant should advise as to whether it will be necessary to revise the site layout significantly in order to resolve the stormwater management concerns described in comments #30 and #31 of the SSM review
- The Commission should advise as to whether you support the waivers from the land- scaping requirements recommended in comment #4 of the Theurkauf review. 4
- The Commission may wish to discuss with the Applicant any plans they may have to improve traffic conditions created by parents dropping off their children, as noted in comment #3 of the Bowman review. Attachments
- SSM review dated September 28, 2026
- Theurkauf review dated September 16, 2026
- Bowman review dated September 23, 2026
- Section 325-9.C(3) – A variance was granted to permit an impervious coverage of 29.9% when only a 15% percent maximum is typically permitted within the R-1 District
- Section 325-71.B – A variance was granted to permit the construction of building additions, athletic fields and associated infrastructure in areas of prohibitive slopes (i.e., >25%)
- Section 325-71.C – A variance was granted to permit the construction of building additions, athletic fields and associated infrastructure in areas of precautionary slopes (i.e., 15% to 25%)
- The variances granted section shall be expanded to note the date of the Zoning Hearing Board approval date of July 23, 2026
- On Sheet 10 variances from Sections 325-71.B and Section 325-71.C shall be revised such that the text reads “to allow the construction” in lieu of “to the allow the construction”.
- Section 281-16.B(2) – Name and contact information for the applicant shall be shown on the plans. The plans shall be expanded to include a WCASD representatives name, their title, and their email address on the plans
- Section 281-16.C(2) – The plans shall list the gross and net lot areas in acres and square feet
- Section 281-16.D(2)(c) – The elevation of the first (i.e., ground) floor shall be shown. Currently, only the entrance to the buildings have elevations
- Section 281-16.D(2)(d) – For nonresidential buildings, the number of stories shall be shown
- Section 281-16.D(6)(e) – For nonresidential buildings, the total floor area shall be shown, in square feet
- Section 281-30.E(2)(a) through (g) – The backfilling requirements of this section shall be added to the plans
- Section 281-48.C(1) – A lighting plan shall be provided and demonstrate that proper illumination levels have been established. Mr. John Weller | West Whiteland Township SSM File 101008.0412 Septermber 28, 2026 Page 5 of
- Section 270-17.A(1)(b) – An NPDES Permit for construction activities will be required. A copy of the approved permit shall be submitted to the Township prior to the Township endorsing the plan
- Sections 270-32.A(3)&(4) – The owner’s acknowledgement statement and design engineer’s signature blocks shall be added to the plans and signed before the Township endorses the plan
- Sections 270-32.B(18)(a) and (c)[2] through (c)[7] – The PCSM plan shall include the items of these sections
- Sections 270-45.C(1) through (3) – The post construction maintenance inspection requirements of these sections shall be noted on the plan
- The plans shall specify the type of “Crate” system proposed for the stormwater management facilities. This shall include manufacturer, size and model type
- The geotextile fabric in the stormwater management facilities shall be specified on the top, bottom and sides of the facility and shall either include specifications, PennDOT 408 type or manufacturer’s name and type
- The plan identifies infiltration test pits TP-101 through TP-104 but they are not mentioned in the Geotechnical report. The results of these tests shall be included in the report
- The drainage area maps shall include the Time of Concentration flow paths
- The design of the infiltration facility shall consider loading ratios
- Stormwater and Erosion & Sediment Control Note number 5 on Sheet 2 shall be revised to reflect West Whiteland Township and West Goshen Township, respectively. GENERAL
- R-2 is listed in the “Site & Adjacent Zoning Districts” on Sheet 1. No portion of the site is actually zoned R-2 Residential District; therefore, reference to the R-2 Residential District shall be removed
- The plans shall note within the demolition notes on Sheet 2 that a West Whiteland Township Demolition permit shall be acquired prior to commencing the demolition of any buildings or structures on site
- The plans shall note that all proposed sanitary sewers shall be in accordance with the West Whiteland Township Sanitary Sewer Standards
- The Concrete curb details on Sheet 28 are in conflict with each other. One indicated a depth of 18-inches, while the other detail indicates a depth of 22 inches
- We recommend the “Project North” compass shall be removed
- The title block for the plans contains a plan date that is not legible. Future submissions shall ensure that the title block does not contain text overlaps and remains legible
- The Township Engineer Review signature block on Sheet 1 shall be removed
- Plan Graphics – The landscape plan should be revised to eliminate graphic conflicts that make some plant labels difficult to read
- REVIEW OF MEETING MINUTES MOTION: To approve the minutes of August 18, 2026, as presented. (Jones/Rouse) ACTION: Passed, 7-0. Hl, = PUBLIC COMMENT There was no public comment on items not on the agenda. IV, PLANS
- The Plan is approved as a Final Plan pursuant to §281-10.H of the West Whiteland Town- ship Subdivision and Land Development Ordinance (“S/LDO”)
- Waiver of §281-37.B(3) of the S/LDO to allow the two undersized parking lot islands south of the Retail Store, pursuant to comment 47 of the Theurkauf Design and Planning (“Theurkauf”) review dated September 25, 2026
- Waiver of §281-43 of the S/LDO to allow above-ground utilities as shown, subject to receipt of confirming communication from PECO,
- Waiver of §281-67.B of the S/LDO to allow the car wash entrance to face the street
- Waiver of §281-69.C(2) of the S/LDO to allow sidewalks with a width of not less than six feet, pursuant to comment #20 of the Spotts, Stevens and McCoy (“SSM”) review dated September 29, 2026
- Waiver of §281-69.C(3) of the $/LDO such that sidewalks are required along only one side of the access drives, as shown on the Plan, pursuant to comment #21 of the SSM review dated September 29, 2026
- The sidewalk configuration depicted on the Plan, with the adjustment agreed to at the meeting of October 6, 2026, is acceptable and is hereby approved by the Township as required by §281-31.A of the $/LDO
- Receipt of approval from the Department of Environmental Protection of the Applicant’s sewage facilities planning module exemption